The physical parameters Have been measured to identify whether the cornmunity traditonal wells have been polluted at the location of final waste destination (TPA) in Muara Fajar. Measuring the physical parameters result the value of permeability the land layers in a location of TPA which is about 3,79x10-5 cm/s to 3,34 x10-3 cm/s. Theses showed that the velocity of the moving a water flow or permeability was small. The result of measuring the land cavacity in a location af the TPA are within the range of 0,15 kg/cm2 to 1,350 kg/cm2 with based width is 1,00 m and depth 1m to 2 m. These result showed that the land cavacity in a location of the TPA was very strong and suitable for location the TPA. The result of analysis the physical parameters of the community well water around the TPA showed that several wells have been polluted by lindi water