ANALISA KEANDALAN SISTEM KESELAMATAN BANGUNAN TERHADAP BAHAYA KEBAKARAN (Studi Kasus Gedung Surya Dumai Group dan Bank Tabungan Negara Kota Pekanbaru)

dc.contributor.authorSafriandi
dc.contributor.authorTrikomara Rian
dc.contributor.authorSebayang Mardani
dc.date.accessioned2013-07-16T06:46:38Z
dc.date.available2013-07-16T06:46:38Z
dc.date.issued2013-07-16
dc.description.abstractFires can occur anytime and anywhere. No workplace can be guaranteed to be free of risk (immune) from fire hazards. Fires in the workplace can bring many consequences which adversely affects both parties nagi employers, workforce and wider community. The impact of fire incidents in the workplace can lead to loss of life, loss of material, loss of jobs and alain indirect losses, especially if there is a fire on the vital objects can impact more broadly. Consequently picture above is a very valuable lesson for the board of supervision K3 especially in the field of fire prevention. At the end of this task is to identify availability and spesific existing fire protection systems in buildings Surya Dumai Group Pekanbaru City and State Savings Bank (BTN) Pekanbaru. Components were identified, namely completeness footprint, the means of salvation, active protection system and passive protection system. Reliability assessment system for fire safety of buildings is done by check-list method using direct survey of the building. The results in the form of value system reliability against fire safety of buildings (NKSKB) in buildings Surya Dumai Group with 22,19% tread completeness assessment, system safety means 15.32%, 19.79% active protection system and passive protection system 21.74%. The level of reliability of fire protection systems in buildings Surya Dumai Group as a whole is "Enough" with a percentage of 79.04%. The results in the form of value system reliability against fire safety of buildings (NKSKB) in buildings Savings Bank Negara (BTN) Pekanbaru with 20.89% tread completeness assessment, system safety means 18.25%, 15.80% active protection system and 19.19% passive protection system.The level of reliability of fire protection systems in buildings Surya Dumai Group as a whole is "Enough" with a percentage of 74.13%.en_US
dc.description.sponsorshipen_US
dc.identifier.otherrio andika
dc.identifier.urihttp://repository.unri.ac.id:80/handle/123456789/4379
dc.language.isootheren_US
dc.subjectbuildingen_US
dc.subjectvalue the reliabilityen_US
dc.subjectcompleteness footprinten_US
dc.subjectthe means of salvationen_US
dc.subjectactive protection systemsen_US
dc.subjectpassive protection systemen_US
dc.titleANALISA KEANDALAN SISTEM KESELAMATAN BANGUNAN TERHADAP BAHAYA KEBAKARAN (Studi Kasus Gedung Surya Dumai Group dan Bank Tabungan Negara Kota Pekanbaru)en_US
dc.typestudent Paper Post Degreeen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
SAFRIANDI (0607113690).pdf
Size:
375.32 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: