PENENTUAN KUALITAS AIR SUNGAI DAN AIR SUMUR SEKITAR SUNGAI SIAK BERDASARKAN SIFAT LISTRIK AIR PADA SUHU 200 C MENGGUNAKAN MULTITESTER

dc.contributor.authorSimbolon, Lundu F
dc.contributor.authorSyech, Riad
dc.contributor.authorEmrinaldi, Tengku
dc.date.accessioned2016-02-01T01:55:54Z
dc.date.available2016-02-01T01:55:54Z
dc.date.issued2016-02-01
dc.description.abstractA study concerning the determination of the quality of river water and well water around the river Siak using the experimental method has been investigated. This research was conducted by measuring the electrical properties of water at a temperature of 20 C. The type of water used were water streams, water dug wells and water wells drilled in obtaining seven points. Measurement of the electrical properties of water was done by using multitester associated with power suppy, the plate of Copper (Cu) and Zinc (Zn) as a conductor, and the glass beaker as a container for the sample. The measurement will show voltage and current values. Based on voltage and current values, they can calculate the value of the electrical properties of each sample. Results of river water has a resistance value of 2255.46 Ω, resistivity of 213.14 Ωm, conductivity of 0.00530 (Ωm)-1, and power of 3.81 x 10-5 W. The electrical properties of best water wells dug well is six with a resistance value of 3136.46 Ω, resistivity 296.39 Ωm, conductivity of 0.00345 (Ωm)-1, and power of 7.85 x 10-5 W. Based on the results, the value of the electrical properties of the best water is the average electrical properties of water well three (drilled wells) with a resistance value of 3538.61 Ω, the electrical resistivity value of 334.39 Ωm, the electrical conductivity value of 0.00341 (Ωm)-1, and electric power of 4,76x10-5W. The water is suitable for consumption having a resistivity of 3x103 Ω, and the electrical conductivity of (300 to 500) x10-6 (Ωm)-1. Based on the standard resistivity and electrical conductivity, the river and well water samples are unfit for human consumption because the values are still far from the exposure limits.en_US
dc.description.sponsorshipFakultas Matematika dan Ilmu Pengetahuan Alam Universitas Riauen_US
dc.identifier.otherwahyu sari yeni
dc.identifier.urihttp://repository.unri.ac.id/xmlui/handle/123456789/7846
dc.language.isoenen_US
dc.subjectWater Qualityen_US
dc.subjectSiak Riveren_US
dc.subjectWellsen_US
dc.subjectWater Electrical Propertiesen_US
dc.titlePENENTUAN KUALITAS AIR SUNGAI DAN AIR SUMUR SEKITAR SUNGAI SIAK BERDASARKAN SIFAT LISTRIK AIR PADA SUHU 200 C MENGGUNAKAN MULTITESTERen_US
dc.typestudent Paper Post Degreeen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
jurnal LUNDU F SIMBOLON (1003135669).pdf
Size:
1007.01 KB
Format:
Adobe Portable Document Format
Description:
artikel
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections