PENGARUH KONSENTRASI OKSIGEN TERLARUT TERHADAP PENGUKURAN SUSEPTIBILITAS MAGNETIK PADA FREKUENSI RENDAH

dc.contributor.authorAsmarita, Yulmaisi Dwi
dc.contributor.supervisorSetiadi, Rahmondia Nanda
dc.date.accessioned2022-09-19T08:50:46Z
dc.date.available2022-09-19T08:50:46Z
dc.date.issued2022-05
dc.description.abstractWater is one of the most valuable natural resources subsequent to the air. The utilization of water can’t be separated from the quality of the water, where poor water conditions are not only an indicator of environmental damage, but also a threat to the ecosystem. One of indicator water quality is determined by dissolved oxygen. In this research, an instrument to measure the effect of dissolved oxygen was built based on the susceptibility value of a solution at low frequencies of 1 Hz, 10 Hz and 100 Hz. The instrument used consists of 217 turns of the primary coil and 30,000 turns of the secondary coil. A magnetic instrument with an RC circuit is designed to produces a magnetic field, which can inspect sample solutions easily and simply. The RC circuit used resistor and capacitor values of 1 MΩ and 10 μF, respectively, which produces a pole frequency of 0.016 Hz. The gradient value of the measurement solution gets smaller when the frequency is increased, the gradient value at the frequency of 1 Hz is greater than at the frequencies of 10 Hz and 100 Hz. The addition of oxygen to main solution aims to produce solutions with a concentration of 0%, 25%, 50%, 75% and 100%. The measurement results show an effect of solution concentration change on the susceptibility value, the greater the concentration of the solution, the susceptibility value increases. The instrument that is built can also detect changes in the value of the gradient on variations in concentration, frequency and diameteren_US
dc.description.sponsorshipFakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Riauen_US
dc.identifier.citationPerpustakaanen_US
dc.identifier.otherElfitra
dc.identifier.urihttps://repository.unri.ac.id/handle/123456789/10685
dc.language.isoenen_US
dc.publisherElfitraen_US
dc.subjectMagnetic Susceptibilityen_US
dc.subjectDissolved Oxygenen_US
dc.subjectCoilen_US
dc.subjectRC Circuiten_US
dc.titlePENGARUH KONSENTRASI OKSIGEN TERLARUT TERHADAP PENGUKURAN SUSEPTIBILITAS MAGNETIK PADA FREKUENSI RENDAHen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Yulmaisi Dwi Asmarita_compressed.pdf
Size:
260.29 KB
Format:
Unknown data format
Description:
artikel
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections