TINGKAT PENYERAPAN INDUKSI MAGNETIK BAHAN PENYERAP YANG DITIMBULKAN OLEH TELEPON SELULER

dc.contributor.authorSarlismi
dc.contributor.authorErwin
dc.contributor.authorGinting, M.
dc.date.accessioned2014-03-26T07:03:35Z
dc.date.available2014-03-26T07:03:35Z
dc.date.issued2014-03-26
dc.description.abstractUsers of cellular telephone (HP) today claim that weak static magnetic fields (B) is induced around the HP and this may affect the users. In this research, measurement of a static magnetic induction and a magnetic moment induced by HP was carried out. The measurement of the static magnetic induction was done for two directions which were horizontal and vertical direction. The static magnetic induction induced by that HP was measured using a magnetic sensor Pasco PS 2112. The effect of the thickness of material such as copper (Cu) inserting between a magnetic probe and the HP was studied. For the horizontal direction (x direction), the magnetic induction was measured with the distance of 0,7 cm from the HP with and without Cu. The static magnetic induction was also measured in vertical direction (z-direction) using 0 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm of absorption materials. The results showed that the static magnetic induction was induced by those HP has normal distribution with the position of the peak near thetop of the HP. The value of magnetic induction was found to be 10-3 T and 9 10 T without and with Cu, respectively. For vertical measurement, it was found that the static magnetic induction reduced its values with increasing distance from the HP. By plotting B versus distance, it was found that the magnetic moment of the HP was 1,5 Am2. Based on these plots, then it was also found that the level of absorption of was about 0,02 mm-1en_US
dc.description.sponsorshipErwin, Ginting, M.en_US
dc.identifier.otherRangga Dwijunanda Putra
dc.identifier.urihttp://repository.unri.ac.id/xmlui/handle/123456789/5898
dc.language.isootheren_US
dc.subjectMagnetic sensor Pasco PS 2112en_US
dc.subjectInduction magneticen_US
dc.subjectMagnetic momentsen_US
dc.subjectAbsorptionen_US
dc.subjectCellular telephoneen_US
dc.titleTINGKAT PENYERAPAN INDUKSI MAGNETIK BAHAN PENYERAP YANG DITIMBULKAN OLEH TELEPON SELULERen_US
dc.typeOtheren_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
karya ilmiah Sarlismi.pdf
Size:
115.63 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections