DSpace Repository

PENENTUAN KUALITAS AIR SUNGAI DAN AIR SUMUR SEKITAR SUNGAI SIAK BERDASARKAN SIFAT LISTRIK AIR PADA SUHU 200 C MENGGUNAKAN MULTITESTER

Show simple item record

dc.contributor.author Simbolon, Lundu F
dc.contributor.author Syech, Riad
dc.contributor.author Emrinaldi, Tengku
dc.date.accessioned 2016-02-01T01:55:54Z
dc.date.available 2016-02-01T01:55:54Z
dc.date.issued 2016-02-01
dc.identifier.other wahyu sari yeni
dc.identifier.uri http://repository.unri.ac.id/xmlui/handle/123456789/7846
dc.description.abstract A study concerning the determination of the quality of river water and well water around the river Siak using the experimental method has been investigated. This research was conducted by measuring the electrical properties of water at a temperature of 20 C. The type of water used were water streams, water dug wells and water wells drilled in obtaining seven points. Measurement of the electrical properties of water was done by using multitester associated with power suppy, the plate of Copper (Cu) and Zinc (Zn) as a conductor, and the glass beaker as a container for the sample. The measurement will show voltage and current values. Based on voltage and current values, they can calculate the value of the electrical properties of each sample. Results of river water has a resistance value of 2255.46 Ω, resistivity of 213.14 Ωm, conductivity of 0.00530 (Ωm)-1, and power of 3.81 x 10-5 W. The electrical properties of best water wells dug well is six with a resistance value of 3136.46 Ω, resistivity 296.39 Ωm, conductivity of 0.00345 (Ωm)-1, and power of 7.85 x 10-5 W. Based on the results, the value of the electrical properties of the best water is the average electrical properties of water well three (drilled wells) with a resistance value of 3538.61 Ω, the electrical resistivity value of 334.39 Ωm, the electrical conductivity value of 0.00341 (Ωm)-1, and electric power of 4,76x10-5W. The water is suitable for consumption having a resistivity of 3x103 Ω, and the electrical conductivity of (300 to 500) x10-6 (Ωm)-1. Based on the standard resistivity and electrical conductivity, the river and well water samples are unfit for human consumption because the values are still far from the exposure limits. en_US
dc.description.provenance Submitted by wahyu sari yeni (ayoe32@ymail.com) on 2016-02-01T01:55:54Z No. of bitstreams: 1 jurnal LUNDU F SIMBOLON (1003135669).pdf: 1031182 bytes, checksum: 59aa651aaabfff38a2c904b6e0def8c8 (MD5) en
dc.description.provenance Made available in DSpace on 2016-02-01T01:55:54Z (GMT). No. of bitstreams: 1 jurnal LUNDU F SIMBOLON (1003135669).pdf: 1031182 bytes, checksum: 59aa651aaabfff38a2c904b6e0def8c8 (MD5) en
dc.description.sponsorship Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Riau en_US
dc.language.iso en en_US
dc.subject Water Quality en_US
dc.subject Siak River en_US
dc.subject Wells en_US
dc.subject Water Electrical Properties en_US
dc.title PENENTUAN KUALITAS AIR SUNGAI DAN AIR SUMUR SEKITAR SUNGAI SIAK BERDASARKAN SIFAT LISTRIK AIR PADA SUHU 200 C MENGGUNAKAN MULTITESTER en_US
dc.type student Paper Post Degree en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account