PEMETAAN LAJU DOSIS RADIASI DI SEKITAR INSTALASI RADIOTERAPI RSUD ARIFIN ACHMAD PEKANBARU

Show simple item record

dc.contributor.author SIMARMATA, RONA INDAH P
dc.date.accessioned 2021-08-31T04:40:02Z
dc.date.available 2021-08-31T04:40:02Z
dc.date.issued 2020-12
dc.identifier.other wahyu sari yeni
dc.identifier.uri https://repository.unri.ac.id/handle/123456789/10196
dc.description.abstract The Regional General Hospital (RSUD) Arifin Achmad Pekanbaru, has installed a Linear Accelerator (LINAC) radiotherapy facility since 2009. Mapping of radiation intensity around LINAC is needed to anticipate the effects caused by radiation sources on workers, patients and the community in the installation environment. This study aims to estimate the accumulated radiation dose received by workers at the Radiotherapy Installation of RUSD Arifin Ahmad Pekanbaru. Mapping of radiation dose rates around the radiotherapy radiation source is made based on the isodosis curve of the measurement of the radiation dose rate of the LINAC radiotherapy. Data were collected at 16 measuring points around the LINAC in a measuring field of 10 m x 10 m. Measurement of radiation dose rate was carried out using a Surveymeter when the LINAC was operating with an absorption dose of 300 MU (monitor unit) with the gantry positions of 0 °, 90 °, 180 ° and 270 °. The radiation dose rate map was made using Surfer software. The measurement results show that points A and B which are at the entrance to the radiation chamber experience the largest dose rate when the gantry angle is 0, with the total radiation dose rate in the radiotherapy installation ranging from (0.92 to 3.23) mSv per year. The radiation dose rate is still below the deterministic effect threshold. Therefore, it can be concluded that the radiation effect received by workers and the community around the radiotherapy installation is a stochastic effect en_US
dc.description.provenance Submitted by wahyu sari yeni (ayoe32@ymail.com) on 2021-08-31T04:40:02Z No. of bitstreams: 1 RONA INDAH_compressed.pdf: 249959 bytes, checksum: 498153d52177417ec543b49c55b3d1a3 (MD5) en
dc.description.provenance Made available in DSpace on 2021-08-31T04:40:02Z (GMT). No. of bitstreams: 1 RONA INDAH_compressed.pdf: 249959 bytes, checksum: 498153d52177417ec543b49c55b3d1a3 (MD5) Previous issue date: 2020-12 en
dc.description.sponsorship Bidang Fisika Medis Jurusan Fisika FMIPA-Universitas Riau Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Riau en_US
dc.language.iso en en_US
dc.subject Radiotherapy LINAC en_US
dc.subject Surveymeter en_US
dc.subject radiation en_US
dc.subject mapping en_US
dc.title PEMETAAN LAJU DOSIS RADIASI DI SEKITAR INSTALASI RADIOTERAPI RSUD ARIFIN ACHMAD PEKANBARU en_US
dc.type Article en_US
dc.contributor.supervisor Rini, Ari Sulistyo