dc.description.abstract |
Experimental studies on Residential Split AC Water Heater
(RSACWH) by replacing refrigerant R-22 with HCR-22
(hydrocarbon refrigerants) as a drop-in substitute has been carried
out. The dummy condenser (trombone type coil) as heat recovery
system was used for heating water and installed in the water tank
with 50 L capacity. The use of HCR-22 save electrical energy due
to decrease in compressor power about 16.31% - 21.64% of the
R-22, because HCR-22 refrigerant mass charge in the
refrigeration system 40% less than the charge of R-22. The
cooling capacity and heat rejection capacity is relatively the same
for R-22 and HCR-22. The COPR increases around 11.89% -
18.69% and COPR + HP also increases around 4.26%-11.41% for
HCR-22 compared to R-22. The room temperature with HCR-22
is relatively the same compared to R-22, while the hot water
temperature using HCR-22 and R-22 are about 46.58°C-48.81°C
and 59.50°C-63.40°C respectively. The use of the HCR-22
provides electrical energy savings for compressor power and
better performance (COP) at similar room temperature compared
to R-22. |
en_US |
dc.description.provenance |
Submitted by wahyu sari yeni (ayoe32@ymail.com) on 2016-04-19T02:43:48Z
No. of bitstreams: 3
cover.pdf: 168497 bytes, checksum: e5508670438336401dcaba5086bd588b (MD5)
daftar isi.pdf: 132152 bytes, checksum: e48d6332bab16f8e95606646c9badd94 (MD5)
18b Proc OMASE 2015 2-1-13.pdf: 1316701 bytes, checksum: d87341758a3d7fe08ddc9d592fe8c523 (MD5) |
en |
dc.description.provenance |
Made available in DSpace on 2016-04-19T02:43:48Z (GMT). No. of bitstreams: 3
cover.pdf: 168497 bytes, checksum: e5508670438336401dcaba5086bd588b (MD5)
daftar isi.pdf: 132152 bytes, checksum: e48d6332bab16f8e95606646c9badd94 (MD5)
18b Proc OMASE 2015 2-1-13.pdf: 1316701 bytes, checksum: d87341758a3d7fe08ddc9d592fe8c523 (MD5) |
en |
dc.description.sponsorship |
he 2nd International Conference on Ocean, Mechanical & Aerospace -scientists & engineers (OMASE 2015) |
en_US |
dc.language.iso |
en |
en_US |
dc.subject |
water heater |
en_US |
dc.subject |
hydrocarbon refrigerant |
en_US |
dc.subject |
trombone coil |
en_US |
dc.subject |
dummy condenser |
en_US |
dc.subject |
heat recovery |
en_US |
dc.title |
Comparative Study of Residential Split Air Conditioner as Water Heater (RSACWH) Using R-22 and HCR-22 Refrigerant |
en_US |
dc.type |
UR-Scientific Work Lecturer |
en_US |