Abstract:
The process of determining the leachate distribution at Muara Fajar Final Disposal, Rumbai,
Pekanbaru has been carried out using geoelectric methods of the Wenner rule and the
Geochemical test. This study aims to determine the distribution of the leachate and analyze
the quality of leachate. Measurements were made on two tracks, each track was 100 meters
long. Based on the results of data processing, it is known that the leachate distribution layer
on track 1 has a depth of 2.25 – 7.46 meters below the surface with a resistivity value of
0.729 – 4.38 Ωm. The leachate distribution layer on track 2 has a depth of 2.25 – 5.56 meters
below the surface with a resistivity value of 1.82 – 10.2 Ωm. The distribution of leachate
found from the result of interpretation is not evenly distributed on each track. The quality
parameters of leachate in Muara Fajar Final Disposal such as pH has a values ranging from
5.29 to 8.30 and concentration of heavy metals Cadmium has a value < 0.0031 Mg/L, Lead <
0.0017 Mg/L. This values are still met the leachate standard parameters. Based on the
standard parameter of clean water where its pH is 4, while the quality of the residents' wells
pH is 5.29, meaning that it is more acidic and is not suitable for human consumption and for
Lead < 0.0017 Mg/L and Cadmium < 0.0031 Mg/L still in accordance with clean water
standard parameters.