This paper presents the experimental performance study to
observe the effect of changes in the cooling load of the combined
air conditioning and water heating system with trombone coil
type as dummy condenser using heat wasted from split type air
conditioner. Effects of the following parameters to the system
performance were examined: compressor power test chamber, test
chamber temperature, condenser temperature, hot water
temperature and Coefficient of Performance (COP). The results
showed that the bigger the cooling load is given in the test
chamber, the bigger the heat absorbed in the evaporator, so the
higher the temperature of the hot water in a tank. COP increased
with increasing of cooling loads. It was concluded that by
combined air conditioning and water heating system so that space
cooling and water heating can take place simultaneously, and the
energy performance can be raised considerably. |
en_US |
dc.description.provenance |
Submitted by wahyu sari yeni (ayoe32@ymail.com) on 2016-04-19T02:39:00Z
No. of bitstreams: 3
cover.pdf: 168100 bytes, checksum: b3160d58ab7901b68411c8a05e0a1669 (MD5)
daftar isi.pdf: 124325 bytes, checksum: 2b50a0c83f2075e75be2a70d0a02b1c1 (MD5)
17 OMASE 2014 4-4.pdf: 447841 bytes, checksum: bca37d7afc9841a3337ca2f8445019a1 (MD5) |
en |
dc.description.provenance |
Made available in DSpace on 2016-04-19T02:39:00Z (GMT). No. of bitstreams: 3
cover.pdf: 168100 bytes, checksum: b3160d58ab7901b68411c8a05e0a1669 (MD5)
daftar isi.pdf: 124325 bytes, checksum: 2b50a0c83f2075e75be2a70d0a02b1c1 (MD5)
17 OMASE 2014 4-4.pdf: 447841 bytes, checksum: bca37d7afc9841a3337ca2f8445019a1 (MD5) |
en |
dc.description.sponsorship |
The 1st International Conference on Ocean, Mechanical & Aerospace -scientists & engineers (OMASE 2014) |
en_US |
dc.language.iso |
en |
en_US |
dc.subject |
air conditioning |
en_US |
dc.subject |
water heater |
en_US |
dc.subject |
cooling load |
en_US |
dc.subject |
COP |
en_US |
dc.subject |
compressor power |
en_US |
dc.title |
Performance of Air Conditioning Water Heater with Trombone Coil Type as Dummy Condenser at Different Cooling Loads |
en_US |
dc.type |
UR-Scientific Work Lecturer |
en_US |